Indoor Sensors(Temperature,Humidity,CO,CO2)
DSW-100_200 Catalog
DSW series

Indoor Sensors
Indoor Temperature Sensor DSW-100-T
DSW-100-T Manual
Indoor Humidity Sensor DSW-100-H
DSW-100-H Manual
Indoor Temperature/Humidity Sensor DSW-100-TH
DSW-100-TxHx Manual
Indoor CO2 Sensor DSW-200-CO2
DSW-200-CO2 Manual

- Model
- Temperature/Humidity Sensor Spec
- CO2 Sensor Spec
- Dimensions
- Terminal Arrangement
- Temperature element: RTD 100/0 (Pt100)
Accuracy: (0.1+0.0017|t|)
(DSW-100-TRx, -TRHx)
- Humidity element: Electrostatic capacity variation type
Connector type for easy replacement
(DSW-100-Hx, -TxHx)
- For temperature sensors with current output, the 2-wire type can be connected to Shinko controllers, resulting in cost reduction.
(DSW-100-TAx, -TAHx)
- CO2 sensor
(DSW-200-CO2)


Model

Indoor Temperature Sensor DSW-100-Txx
DSW-100
-T
Measurement target -T Temperature
Output spec. 1 R 100/0 (Pt100)
A 4 to 20 mA DC
Output spec. 2 (*)
2-wire type
W4 4-wire type
(*) Available for the DSW-100-TA.

Indoor Humidity Sensor DSW-100-Hx
DSW-100
-H
Measurement target -H Humidity
Output spec. 2-wire
W4 4-wire


Indoor Temperature/Humidity Sensor DSW-100-TxHx
DSW-100
-T H
Measurement target 1 -T Temperature
Output spec. 1 R 100/0 (Pt100)
A 4 to 20 mA DC
Measurement target 2 H Humidity
Output spec. 2 4 to 20 mA DC(2-wire type)
W4 4 to 20 mA DC(4-wire type)
V W4 0 to 1 V DC(4-wire type)(*)
(*) Available for the DSW-100-TRH.


Indoor CO2 Sensor DSW-200-CO2-xxx

DSW-200
-CO2 -
Measurement target -CO2 CO2 density
Measurement range -1 360 to 2000 ppm(with Sensor Correction Function)
-2 360 to 5000 ppm(with Sensor Correction Function)
Output spec. 1   4 to 20 mA DC
2   0 to 20 mA DC
3   1 to 5 V DC
4   0 to 5 V DC
5   0 to 1 V DC
Moisture-proof treatment 0 Unavailable
1 Available
to top


Temperature/Humidity Sensor Spec
Rating
Measurement Range
DSW-100-Txx 0 to 50
DSW-100-Hx 5 to 90 %RH
DSW-100-TxHx Temperature: 0 to 50, Humidity: 5 to 90 %RH

Output
DSW-100-TRx 100/0 (Pt100) 3-wire type
DSW-100-TAx 4 to 20 mA DC (Linear conversion corresponding to 0 to 50)
2-wire or 4-wire types, selectable
Max allowable load: 500 or less
DSW-100-Hx 4 to 20 mA DC (Linear conversion corresponding to 0 to 100 %RH)
2-wire or 4-wire types, selectable
Max allowable load: 500 or less
DSW-100-TRHV W4 Temperature 100/0 (Pt100) 3-wire type
Humidity 0 to 1 V DC (Linear conversion corresponding to 0 to 100 %RH)
4-wire type
Max allowable load: 500 or less
DSW-100-TAHx Temperature 4 to 20 mA DC (Linear conversion corresponding to 0 to 50)
2-wire or 4-wire types, selectable
Max allowable load: 500 or less
Humidity 4 to 20 mA DC (Linear conversion corresponding to 0 to 100 %RH)
2-wire or 4-wire types, selectable
Max allowable load: 500 or less
0 to 1 V DC (Linear conversion corresponding to 0 to 100 %RH)
4-wire type
Max allowable load: 500 or less
Supply Voltage
DSW-100-TRx No power needed
DSW-100-TAx 24 V DC10%
DSW-100-Hx
DSW-100-TxHx

General Structure
Element Type
DSW-100-Txx RTD 100/0 (Pt100)
DSW-100-Hx Electrostatic capacity variation type
DSW-100-TxHx Temperature RTD 100/0 (Pt100)
Humidity Electrostatic capacity variation type

Mounting To the outlet box (inside wall), via outlet box cover: mounting dimension: 66.7 mm (JIS-C8340: 1999).
Material Flame-resistant PC resin, Color: White
Performance
Accuracy
DSW-100-TRx (0.1+0.0017|t|)
DSW-100-TAx 0.5
DSW-100-Hx 5 %RH (at 5 to 45), Outside of 5 to 45: Max. 8 %RH
DSW-100-TRHx Temperature (0.1+0.0017|t|)
Humidity 5 %RH (at 5 to 45), Outside of 5 to 45: Max. 8 %RH
DSW-100-TAHx Temperature 0.5
Humidity 5 %RH (at 5 to 45), Outside of 5 to 45: Max. 8 %RH

Response Characteristics
DSW-100-Txx 63 % response within 1 minute (at 1.5 m/s wind velocity)
DSW-100-Hx Approx. 20 seconds (90 % change can be reached within 1 minute in 30-85 %RH range.)
DSW-100-TxHx Temperature 63 % response within 1 minute (at 1.5 m/s wind velocity)
Humidity Approx. 20 seconds (90 % change can be reached within 1 minute in 30-85 %RH range.)

Other
Power consumption 2-wire type: Approx. 550 mW (Output 4 to 20 mA DC)
4-wire type: Approx. 3 W (DSW-100-H W4)
4-wire type: Approx. 4 W (DSW-100-TA W4, DSW-100-TAH W4)
Operating Environment Temperature: 0 to 50
Humidity: 5 to 90 %RH (non-condensing)
Storage Environment Temperature: -20 to 60
Humidity: 5 to 90 %RH (non-condensing)
Weight Approx. 90 g
Insulation Resistance Case-Output: 500M or more, at 500 V DC
Dielectric Strength Case-Output: 1.5 kV for 1 minute, 3 mA or less
Accessories Included Sensor main unit mounting screw (M3 x 4): 4 pieces
Mounting plate: 1 piece
Mounting plate screw (M4 x 8, Spring washer): 2 pieces each
Instruction manual: 1 copy
Environmental Specification RoHS directive conformance
to top


CO2 Sensor Spec
Rating
Measurement Range
DSW-200-CO2-1xx 360 to 2000 ppm
(with Sensor Correction Function)
DSW-200-CO2-2xx 360 to 5000 ppm
(with Sensor Correction Function)

Output
DSW-200-CO2-x1x 4 to 20 mA DC
DSW-200-CO2-x2x 0 to 20 mA DC
DSW-200-CO2-x3x 1 to 5 V DC
DSW-200-CO2-x4x 0 to 5 V DC
DSW-200-CO2-x5x 0 to 1 V DC

<Output of CO2 Sensor>

For each range of CO2 concentration,linearly outputs corresponding to CO2 concentration. However, if the measured value is lower than 360 ppm,the value corresponding to 360 ppm will be output.
Output of CO2 Sensor
Supply Voltage 24 V DC10%
General Structure
Measurement Method Non dispersive infrared (NDIR)
Mounting To the outlet box (inside wall), via outlet box cover: mounting dimension: 66.7 mm (JIS-C8340: 1999).
Material Flame-resistant PC resin, Color: White
Performance
Accuracy (50ppm + 3 % of measured value).
Warm-up period: 30 minutes
Note: Accuracy described here is the accuracy of factor
         shipment.
         Accuracy after shipment changes.
Response Characteristics Within 120 seconds
Sensor Correction One cycle is equivalent to 45 days, and if the measured value drops below 400 ppm in the current cycle, the lowest value in the current cycle will become 400 ppm in the next cycle, and the difference between the lowest value and 400 ppm will be added to all other measured values in the next cycle.
Other
Power Consumption Approx. 3 W
Operating Environment Temperature: 0 to 50
Humidity: 0 to 95 %RH (non-condensing)
Storage Environment Temperature: -30 to 70
Humidity: 0 to 95 %RH (non-condensing)
Weight Approx. 100 g
Insulation Resistance Case-Output: 500 M or more, at 500 V DC
Dielectric Strength Case-Output: 1.5 kV for 1 minute, 3 mA or less
Accessories Sensor main unit mounting screw (M3 x 4): 4 pieces
Mounting plate: 1 piece
Mounting plate screw (M4 x 8, Spring washer): 2 pieces each
Instruction manual: 1 copy
Environmental Specification RoHS directive conformance
to top

Dimensions
DSW-100 External dimensions
to top

Terminal Arrangement
DSW-100-TR

DSW-100-TR Termina Arrangement

DSW-100-TA

DSW-100-TA Termina Arrangement

DSW-100-TA W4

DSW-100-TA W4 Termina Arrangement

DSW-100-H

DSW-100-H Termina Arrangement

DSW-100-H W4

DSW-100-H W4 Termina Arrangement

DSW-100-TAH

DSW-100-TAH Termina Arrangement

DSW-100-TAH W4

DSW-100-TAH W4 Termina Arrangement

DSW-200-CO2-□□□

DSW-100-CO2 Termina Arrangement

to top


CE마킹적합품 / UL취득제품 | 생산종료제품
사이트맵 | 이용조건 | 개인정보보호 관련 | 품질 및 환경활동