Shinko SHINKO TECHNOS CO.,LTD.
취급제품 고객지원/다운로드 회사소개 문의  
일본어
영어
Temperature & Programble Controllers Indicators Communication Converters Recorders Portable Indicator Input Devices Output Devices
HOME
취급제품
온도제어 관련・주변기기
지시조절계・온도조절계
프로그램 컨트롤러
디지털 지시계
통신변환기
기록계
휴대형 지시계
센서・검출단
SSR・전력조절기
신호변환기
수질관리 제품
 
CE 마킹적합품
UL 취득제품
생산종료제품
이용조건
개인정보보호 관련
품질 및 환경활동
Solid State Relay
SA-500 Catalog
SA-500 Instruction Manual
SA-500  

- Keeps the cost down for customized systems
- Built-in 'varistor' for absorbing external surges
- Easily viewable LED status indicator
- Highly insulated: dielectric strength between input and output: 4000 V
- Output side terminal cover is standard. (Input side is optional.)

- Model
- Dimensions
- Spec
 



Model

SA-5
-
Maximum load current 15 15 A
25 25 A
40 50 A
Output Z Zero voltage switching system

Dimensions
  SA-515-Z, SA-525-Z, SA-540-Z
 
SA-500 External Dimensions
   
  Heat Sink AQP813 (for SA-515-Z, SA-525-Z) (Sold separately) (Scale: mm)
 
   
  Heat Sink AQP815 (for SA-540-Z) (Sold separately) (Scale: mm)
 
   
  Terminal Cover (TC-SA5) (Sold separately) (Scale: mm)
  Terminal Cover External dimensions
 
to top


Spec
Rating

Rating (At 20 of ambient temperature)

Model
SA-515-Z
SA-525-Z
SA-540-Z
Input side Control voltage
4 to 32 V DC
Input current
20 mA or less
Recovery voltage
1 V or more
Output side Maximum load current
15 A
25 A
40 A
Load voltage
75 to 250 V AC 45 to 65 Hz
Surge-on current (*1)
150 A
250 A
400 A
'OFF-state' leakage current
10 mA or less (60 Hz)
'ON-state' voltage drop
1.6 V or less (When applying maximum load)
Minimum load current (*2)
100 mA
(*1) 60 Hz, 1 cycle
(*2) When load current is lower than (and including) the rated load current,
use a dummy resistor so that the load current can become 100 mA or more.

Measurement range 0 to 2000 ppm, 0 to 5000 ppm (must be specified)
Output 4 to 20 mA DC, 1 to 5 V DC (must be specified)
Supply voltage 24 V DC10%

Performance
Model
SA-515-Z
SA-525-Z
SA-540-Z
Remarks
Dielectric strength
Input-Output: 4000 V AC
Input-Case: 2500 V AC
For 1 minute
Operating temperature
-20 to 80
No icing at low temperature, and non-condensing
Storage temperature
-20 to 85
Control Voltage and Current Characteristics Characteristics of Control Voltage and Current
Ambient Temperature and Load Current SA-515-Z

SA-525-Z
SA-525-Z Ambient Temperature and Load Current
SA-540-Z
SA-540-Z Ambient Temperature and Load Current

① When mounted to the AQP813 type heat sink.
② When mounted to the AQP815 type heat sink.
③ When used without heat sink.

The SA-500 can be used at an ambient temperature within the curved line indicated in the above diagrams.
Safety Standards
CE Marking
EMC Emission specifications
EN61000-6-4
EN55011 Group 1, Class A
EMC Immunity specifications
EN61000-6-2
LVD VDE-REG-Nr.D553(EN60950-1)
Other
Control System Zero voltage switching system
Weight Approx. 70 g
Accessories Included Instruction manual 1 copy
Accessories Sold Separately
Terminal cover TC-SA5
Heat sink AQP813 (for SA-515-Z, SA-525-Z)
AQP815 (for SA-540-Z)
to top



CE마킹적합품 / UL취득제품 | 생산종료제품
사이트맵 | 이용조건 | 개인정보보호 관련 | 품질 및 환경활동
Copyright (C) 2003-2024 Shinko Technos Co., Ltd. All rights reserved.